Research Article Open Access

Study of Modified Oral Minimal Model using n-Order Decay Rate of Plasma Insulin for the Oral Glucose Tolerance Test in Subjects with Normal, Impaired and Diabetic Glucose Tolerance

Agus Kartono1, Egha Sabila Putri1, Ardian Arif Setiawan1, Heriyanto Syafutra1 and Tony Sumaryada1
  • 1 Computational Biophysics and Molecular Modelling Research Group (CBMoRG), Department of Physics, Faculty of Mathematical and Natural Sciences, Bogor Agricultural University (IPB), Jalan Meranti, Building Wing S, 2nd Floor, Kampus IPB Dramaga, Bogor 16680, Indonesia

Abstract

In this present study, the modified Oral Minimal Model (OMM), with secretion of insulin from pancreas was assumed that the insulin decay rate was not always a first-orderly process in the Oral Glucose Tolerance Test (OGTT), had been developed to study Normal Glucose Tolerance (NGT), Impaired Glucose Tolerance (IGT or pre-diabetes) and type 2 Diabetes Mellitus (T2DM) subjects. The modified OMM model was used to assess physiological functions which were insulin sensitivity (SI) and glucose effectiveness (SG) from the OGTT data. The results of the modified OMM model fit to the measured glucose and insulin concentration-time profiles in the OGTT process of the subjects. The single-step fitting process to optimize the real pAarameters of the SI and SG index from the experimental data using the modified OMM. Our results showed that all NGT subjects had higher the SI and SG index than all IGT and T2DM subjects following the OGTT process. Basal and large peak glucose were lower in all NGT subjects than in all IGT and T2DM subjects. Insulin extraction was lower in all subjects with T2DM but was almost similar for the NGT and IGT subjects. The averaged correlation between measured and this present model, commonly called R2 value, showed that these four cases were 0.96 which indicated good agreement.

American Journal of Applied Sciences
Volume 14 No. 4, 2017, 426-435

DOI: https://doi.org/10.3844/ajassp.2017.426.435

Submitted On: 16 October 2016 Published On: 25 April 2017

How to Cite: Kartono, A., Putri, E. S., Setiawan, A. A., Syafutra, H. & Sumaryada, T. (2017). Study of Modified Oral Minimal Model using n-Order Decay Rate of Plasma Insulin for the Oral Glucose Tolerance Test in Subjects with Normal, Impaired and Diabetic Glucose Tolerance. American Journal of Applied Sciences, 14(4), 426-435. https://doi.org/10.3844/ajassp.2017.426.435

  • 4,011 Views
  • 1,981 Downloads
  • 2 Citations

Download

Keywords

  • Glucose Effectiveness
  • Insulin Sensitivity
  • Mathematical Model
  • Oral Glucose Tolerance Test
  • Type 2 Diabetes Mellitus