Research Article Open Access

The Effect of Thyristor Controlled Series Capacitor on Transient Stability of Single Machine Infinite Bus System with the Exact Short Transmission Line Model

Prechanon Kumkratug1
  • 1 Division of Electrical Engineering, Faculty of Engineering at Si Racha, Kasetsart University, 199 M. 6, Tungsukhla, Si Racha, Chonburi, 20230, Thailand

Abstract

Problem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues, costs of construction and deregulation policies that were introduced in recent years. The Thyristor Controlled Series Capacitor (TCSC) has been proposed for better control power flow and dynamic performance. The exact short transmission line model consists of the resistance and reactance. Most of previous researches studies transient stability performance of TCSC in SMIB System while neglecting the resistance of the line. Thus the full capability of the TCSC on transient stability improvement of power system may not be applied. The consideration of the resistance causes difficulty of deriving the mathematical model. Approach: This study investigates the effect of the TCSC on transient stability of the power system with consideration the exact short transmission line mode. The concept of two-port network is applied to simplify the mathematical model of the power system. The proposed method is tested on sample system and compared on various cases. Results: The first swing of rotor angle curve of the faulted system without resistance is obviously higher than that of with resistance whereas the second swing of the faulted system without resistance is slightly less than that of with resistance. The system with a TCSC can improve transient stability of power system. Conclusion: It was found from this study that the TCSC and resistance of the line can improve first swing of rotor angle. However, the resistance of the line provides the negative effect on second swing of rotor angle. The simulation results indicate that for practical short line, the resistance is a very important parameter for evaluating transient stability of power system.

American Journal of Applied Sciences
Volume 9 No. 3, 2012, 425-428

DOI: https://doi.org/10.3844/ajassp.2012.425.428

Submitted On: 11 November 2011 Published On: 2 February 2012

How to Cite: Kumkratug, P. (2012). The Effect of Thyristor Controlled Series Capacitor on Transient Stability of Single Machine Infinite Bus System with the Exact Short Transmission Line Model. American Journal of Applied Sciences, 9(3), 425-428. https://doi.org/10.3844/ajassp.2012.425.428

  • 3,034 Views
  • 2,791 Downloads
  • 2 Citations

Download

Keywords

  • Power system stability
  • transient stability
  • critical clearing time
  • FACTS devices
  • resistance
  • reactance
  • capacitance
  • transmission line
  • short transmission line
  • two-port network