TY - JOUR AU - Megri, Ahmed Cherif AU - Yu, Yao AU - Sobers, Akeel AU - Cooper, Alyssa PY - 2014 TI - ILLUMINANCE EVALUATION AND ASSESSMENT AT THREE ELEMENTARY SCHOOLS JF - American Journal of Engineering and Applied Sciences VL - 7 IS - 1 DO - 10.3844/ajeassp.2014.129.136 UR - https://thescipub.com/abstract/ajeassp.2014.129.136 AB - A simplified model for illuminance prediction has been developed to estimate the indoor level of lighting under artificial lighting. As well, illuminance in several locations of three schools has been measured under several conditions: Blinds up/lights on, blinds up/lights off, blinds down/lights on, blinds down/lights off. The experimental data of the case "blinds down/lights on" has been compared to the model developed and the results are very encouraging. The purpose of this study is to identify the level of illuminance in elementary schools classroom, to compare it to the IES requirements and the values predicted by the program developed. A parametric study has been performed to study the effect of the Light Loss Factor (LLF) and the luminous power on the lighting and energy performance of the illumination system.